Cisco 350-080 Exam Dumps New Updated By Braindump2go Guarantee 100% Success! (151-160)

CISCIO NEW UPDATED: New Updated 350-080 Exam Questions from Braindump2go 350-080 PDF Dumps and 350-080 VCE Dumps! Welcome to Download the Newest Braindump2go 350-080 VCE&PDF Dumps: http://www.braindump2go.com/350-080.html (394 Q&As)

350-080 Exam Dumps are recently new updated by Cisco Official! Braindump2go also updates all the 350-080 Exam Questions and now all the 394q are the latest(add many new questions this time)! Braindump2go is famous for our AMAZING 99.6% exam pass rate. Join our success! Then you can pass 350-080 Exam successfully under our professional help! We guarantee!

Vendor: Cisco
Exam Code: 350-080
Exam Name: CCIE Data Center Written Exam

350-080 Dumps,350-080 Exam Dumps,350-080 Brainfump,350-080 Questions,350-080 VCE,350-080 PDF,350-080 Actual Test,350-080 Study Guide,350-080 Book,350-080 CCIE Data Center Written Exam,350-080 Test

QUESTION 151
The network administrator is adding a new N1Kv to the vCenter, however, the administrator does not see the new switch under the networking tab of vCenter. The administrator issues the following command on the VSM to troubleshoot:
VSM# show svs connections
connection VC:
ip address: 10.10.10.30
remote port: 80
protocol: vmware-vim https
certificatE. default
datacenter namE. DC1
DVS uuiD. 67 32 30 50 a6 d2 49 64-9e 1c 5f 49 e3 af 55 99 config status: Disabled
operational status: Disconnected
sync status: –
version: –
When attempting to fix the issue, the following error is seen:
VSM-PRI-188# conf
VSM-PRI-188(config)# svs connection VC
VSM-PRI-188(config-svs-conn)# connect
ERROR: [VMWARE-VIM] Extension key was not registered before its use
What is the cause of the error?

A.    Missing control VLAN in VSM configuration
B.    Missing packet VLAN in VSM configuration
C.    VSM has no network connection to vCenter
D.    VSM extension key is not installed on vCenter
E.    vCenter extension key is not installed on VSM

Answer: D

QUESTION 152
Refer to the exhibit. An ESX host is added to a distributed switch but is never seen as a module in VSM. Given below configuration from VSM, what is the cause of this issue? (Choose two.)

VSM# show svs domain
SVS domain config:
Domain iD. 111
Control vlan: 500
Packet vlan: 501
L2/L3 Control modE. L2
L3 control interfacE. NA
Status: Config push to VC successful.

A.    Missing VLAN 500 on Switch1 trunk to Switch2
B.    Missing VLAN 501 on Switch1 trunk to Switch 2
C.    VLAN 500 is not created on Switch2
D.    Interface VLAN 500 is missing on Switch1
E.    Interface VLAN 501 is missing on Switch1
F.    VLAN 111 is missing on all switches

Answer: AC

QUESTION 153
Why is a Cisco UCS B250 server unable to support 16-GB DIMMs?

A.    Dual-rank DIMMs are not supported.
B.    16-GB DIMMs are too slow.
C.    The largest DIMM an Intel 55xx or 56xx CPU can address is 32 GB.
D.    The memory bus would be too long.
E.    The blade would run too hot.

Answer: C

QUESTION 154
On a Cisco UCS B250 M2 server that is fully populated with 1333-MHz memory and an E5640 CPU, what is the fastest speed the memory can run at?

A.    800 MHz
B.    900 MHz
C.    1066 MHz
D.    1333 MHz
E.    1666 MHz

Answer: C

QUESTION 155
Which two servers support memory extension technology and give list? (Choose two.)

A.    B200
B.    C210
C.    B250
D.    C260
E.    C460

Answer: CD

QUESTION 156
Which two statements about NPIV are true? (Choose two.)

A.    After enabling NPIV, switch interfaces can only be placed into NP, F, or SD modes of operation.
B.    NPV devices log in to NPIV devices.
C.    NPIV requires the Enterprise License Package.
D.    NPIV is supported on the Cisco MDS, N7K, and N5K families of switches.
E.    A director class switch should not be placed into NPIV mode.

Answer: BD

QUESTION 157
On a Cisco UCS B250 server, how many physical DIMM slots make up one logical DIMM?

A.    2
B.    3
C.    4
D.    6
E.    12

Answer: A

QUESTION 158
Which statement about NPIV is true?

A.    NPIV provides a means to assign multiple Fibre Channel IDs to a single N-port.
B.    NPIV can be enabled on a per-VSAN basis.
C.    NPIV requires a “write erase” and then reload the switch in order to come up into NPIV mode.
D.    NPIV is a Cisco proprietary feature and as such works only between two Cisco switches.
E.    NPIV must not be enabled on a switch that is also running N-port virtualization.

Answer: A

QUESTION 159
When it comes to creating pooled WWN objects, it is important to understand that a Cisco UCS WWN pool can include only WWNNs or WWPNs from which value of ranges?

A.    from 10:00:00:00:00:00:00:00 to 10:FF:FF:FF:FF:FF:FF:FF
B.    from 20:00:00:00:00:00:00:00 to 20:FF:FF:FF:FF:FF:FF:FF
C.    from 30:00:00:00:00:00:00:00 to 30:FF:FF:FF:FF:FF:FF:FF
D.    from 40:00:00:00:00:00:00:00 to 40:FF:FF:FF:FF:FF:FF:FF

Answer: B

QUESTION 160
Cisco UCS Manager provides the ability to manage power utilization to the blades. Which two statements about UCS Manager power policies are true? (Choose two.)

A.    Power capping helps mainly in reducing data center footprint.
B.    Power capping helps reduce data center cooling.
C.    A single power cap group policy allows you to set power limits across multiple UCS domains.
D.    You can have multiple power cap groups per UCS domain.
E.    Each blade within a UCS 5108 chassis can belong to a separate power cap group.

Answer: BD


Braindump2go New Released 350-080 Dumps PDF are Now For Free Download, 394 Latest Questions, Download It Right Now and Pass Your Exam 100%:

FREE DOWNLOAD: NEW UPDATED 350-080 PDF Dumps & 350-080 VCE Dumps from Braindump2go: http://www.braindump2go.com/350-080.html (394 Q&A)